N-glycan kit #HCP0031A


N-glycan analysis has become a CQA for a number of therapeutic proteins. The N-glycan kit by Genetix is used for analysis of N-glycans present in mAbs by fast enzymatic release by PNGase F and rapid labeling by MS reagent. The labeled N-glycans can then be analyzed on UPLC-FLR based chromatographic system. The label is MS compatible, therefore, the N-glycan peaks can be easily characterized on LC-MS. The kit has reduced the sample preparation time from days in conventional methods to minutes. It can be used for analysis of all proteins containing N-glycans.

Compare

N-glycan analysis has become a CQA for a number of therapeutic proteins. The N-glycan kit by Genetix is used for analysis of N-glycans present in mAbs by fast enzymatic release by PNGase F and rapid labeling by MS reagent. The labeled N-glycans can then be analyzed on UPLC-FLR based chromatographic system. The label is MS compatible, therefore, the N-glycan peaks can be easily characterized on LC-MS. The kit has reduced the sample preparation time from days in conventional methods to minutes. It can be used for analysis of all proteins containing N-glycans.

Category:
Module Model 1 (24T/kit) Model 2 (96T/kit)
Component Storage Component Storage
Deglycosylation

Module

(HCP0031A-1)

IgG (1.2 mg) 2-8℃,12 months IgG (5 mg) 2-8℃,12 months
PNGase F (45 µL) -25℃ ~ -15, 12 months, avoid

freeze/thaw cycles

PNGase F (150 µL) -25℃ ~ -15, 12 months, avoid

freeze/thaw cycles

PNGase F buffer (0.5 mL) 2-8℃,12 months PNGase F buffer (1.0 mL) 2-8℃,12 months
Surfactant (1.2 mg*6) Room Temperature, 12 months Surfactant (3.6 mg*8) Room Temperature, 12 months
Labeling Module (HCP0031A-2) MS reagent powder (8.2 mg*3) 2-8℃,12 months, keep in dark MS reagent powder (24.6  mg*4) 2-8℃,12 months, keep in dark
Anhydrous DMF (1 mL) Room temperature, 12 months Anhydrous DMF (1 mL) Room temperature, 12 months
Clean-up Modue (HCP0031A-3) Elution Plate (96 well) Room temperature, once opened, the

unused well need to be sealed with the

plastic paraffin film and keep

desiccant at room temperature

Elution Plate (96 well) Room temperature, once opened, the

unused well need to be sealed with the

plastic paraffin film and keep

desiccant at room temperature

Elution Buffer (5 mL*1) Room temperature, 12 months Elution Buffer (5 mL*4) Room temperature, 12 months
Sample Diluent (5 mL*1) Room temperature, 12 months Sample Diluent (5 mL*4) Room temperature, 12 months
Sample Collection Module (HCP0031A-4) 8-tube Strips (200 µL) (100 pieces) Room temperature, 96 well collection

plate be sealed and keep desiccant at room temperature

8-tube Strips (200 µL) (100 pieces) Room temperature, 96 well collection

plate be sealed and keep desiccant at room temperature

8-cap Strips (100 pieces) 8-cap Strips (100 pieces)
Collection plate(96 well) Collection plate(96 well)
Waste tray Waste tray